RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show VPTT teststand results


Detector specification:  
Serial: UA1232
Type: Hamamatsu Vacuum Photo Tetrode
   
Measurement results:  
Amplitude: 320.931 ± 10.9692
Normalized Amplitude: 1.37632 ± 0.0373877
Energy: 1587.61 ± 53.2258
Normalized Energy: 1.37714 ± 0.0317257
  Note: The errors given above are the RMS of the histogram from which the mean value was derived.
Created: Thu, 13. September 2018 17:54:05 CEST
Notes: Low Gain