RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA0189


This is all the information about the unit UA0189. If it is wrong, edit the data.

Unit specification:  
Database number: 755
Detector: Hamamatsu Vacuum Photo Tetrode UA0189
Submodule: 30012015-4 - 3-X1Y2-Dprevious (C) • in submodule • next (E)
Crystal: 280
Barcode: 1309008025
   
Measured data:  
Yield (cosmics) for VPTT: 2.0483 ± 0.0228 at 943.2 V and -24 °C
Length: 0 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA0189
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 75
   
Measured data:  
DC gain: 55.18
Anode dark current: 0.004609 nA
Yield: 0
Notes:


Glueing photos

Creation time Notes
18. Oct 2018 12:48:06 CEST
18. Oct 2018 12:48:11 CEST


Upload new photo...

Teststand results

Creation time Detector Notes
04. Nov 2018 00:52:15 CET VPTT High Gain
04. Nov 2018 00:52:15 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
01. Apr 2022 16:10:08 CEST seifen Updated cosmis calibration results via API.
18. Oct 2018 12:44:40 CEST fgrimm Assigned to submodule by script
18. Oct 2018 12:44:30 CEST fgrimm Auto-created by unit assembly script