RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA1824


This is all the information about the unit UA1824. If it is wrong, edit the data.

Unit specification:  
Database number: 70
Detector: Hamamatsu Vacuum Photo Tetrode UA1824
Submodule: 06052014-3 - 1-X1Y4-Cprevious (B) • in submodule • next (D)
Crystal: 4351
Barcode: 1309000746
   
Measured data:  
Yield (cosmics) for VPTT: 2.9372 ± 0.0359 at 776.4 V and -24 °C
Length: 75 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA1824
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 947
   
Measured data:  
DC gain: 47.13
Anode dark current: 0.04786 nA
Yield: -1
Notes:


Glueing photos

Creation time Notes
05. Jul 2017 15:15:46 CEST PR-1200 glueing + 1kg pressure. Crystal damaged, 90° side corner missing


Upload new photo...

Teststand results

Creation time Detector Notes
No teststand results available!

 
 

Version history

Time Author Change comment
30. Mar 2022 18:54:10 CEST seifen Updated cosmis calibration results via API.
08. Oct 2018 15:58:00 CEST fgrimm assigned to submodule, removed old notes
14. Sep 2018 14:57:19 CEST Tobias Unassigned from submodule because assignment was done according to old matching.
06. Apr 2018 13:57:32 CEST cschnier Changed Submodule from Pos 7 to C in NewTestSubmodule
07. Jun 2017 11:51:52 CEST cschnier Assigned to alveole by script
07. Jun 2017 11:51:33 CEST cschnier Auto-created by unit assembly script