RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA0775


This is all the information about the unit UA0775. If it is wrong, edit the data.

Unit specification:  
Database number: 445
Detector: Hamamatsu Vacuum Photo Tetrode UA0775
Submodule: 13062014-1 - 4-X3Y2-Cprevious (B) • in submodule • next (D)
Crystal: 1290
Barcode: 1309005567
   
Measured data:  
Yield (cosmics) for VPTT: 2.3366 ± 0.0273 at 948.1 V and -24 °C
Length: 0 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA0775
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 147
   
Measured data:  
DC gain: 52.36
Anode dark current: 0.046339 nA
Yield: 0
Notes:


Glueing photos

Creation time Notes
24. Aug 2018 15:46:22 CEST PR-1200 glueing + 1kg pressure +16h


Upload new photo...

Teststand results

Creation time Detector Notes
04. Nov 2018 00:43:18 CET VPTT High Gain
04. Nov 2018 00:43:18 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:55:07 CEST seifen Updated cosmis calibration results via API.
24. Aug 2018 15:41:23 CEST mario Assigned to submodule by script
24. Aug 2018 15:17:18 CEST mario Auto-created by unit assembly script