Show unit UA1023
This is all the information about the unit UA1023. If it is wrong, edit the data.
Unit specification: | |
---|---|
Database number: | 44 |
Detector: | Hamamatsu Vacuum Photo Tetrode UA1023 |
Submodule: | 11072014-2 - 3-X1Y5-Fprevious (E) • in submodule • next |
Crystal: | 700 |
Barcode: | 1309000487 |
Measured data: | |
Yield (cosmics) for VPTT: | 2.7885 ± 0.0252 at 999 V and -24 °C |
Length: | 75 mm |
Notes: |
Detector
Detector specification: | |
---|---|
Serial number: | UA1023 |
Type: | Hamamatsu Vacuum Photo Tetrode |
Preamp: | 861 |
Measured data: | |
DC gain: | 48.06 |
Anode dark current: | 0.042283 nA |
Yield: | 0 |
Notes: |
Glueing photos
Creation time | Notes |
---|---|
18. Apr 2017 16:28:57 CEST | PR-1200 glueing + 1kg pressure |
Teststand results
Creation time | Detector | Notes |
---|---|---|
12. Nov 2018 14:35:39 CET | VPTT | High Gain |
12. Nov 2018 14:35:39 CET | VPTT | Low Gain |
Version history
Time | Author | Change comment |
---|---|---|
30. Mar 2022 18:54:42 CEST | seifen | Updated cosmis calibration results via API. |
25. Oct 2018 15:15:49 CEST | fgrimm | assigned to submodule |
14. Sep 2018 14:50:31 CEST | Tobias | Unassigned from submodule because assignment was done according to old matching. |
18. Apr 2017 16:58:32 CEST | cschnier | Changed position. |
18. Apr 2017 16:28:42 CEST | cschnier | Assigned to alveole by script |
18. Apr 2017 16:27:25 CEST | cschnier | Auto-created by unit assembly script |