Show unit UA0217
This is all the information about the unit UA0217. If it is wrong, edit the data.
Unit specification: | |
---|---|
Database number: | 415 |
Detector: | Hamamatsu Vacuum Photo Tetrode UA0217 |
Submodule: | 10032014-02 - 4-X1Y3-6previous (5) • in submodule • next (7) |
Crystal: | 784 |
Barcode: | 1309005031 |
Measured data: | |
Yield (cosmics) for VPTT: | 2.2928 ± 0.0175 at 951.1 V and -24 °C |
Length: | 0 mm |
Notes: |
seems that crystal 785 and 784 swapped in their packagings -> check: 785 should be glued, but 785 is currently at Bochum -> 784 was therefore glued |
Detector
Detector specification: | |
---|---|
Serial number: | UA0217 |
Type: | Hamamatsu Vacuum Photo Tetrode |
Preamp: | 19 |
Measured data: | |
DC gain: | 57.21 |
Anode dark current: | 0.000487 nA |
Yield: | 0 |
Notes: |
Glueing photos
Creation time | Notes |
---|---|
24. Aug 2018 14:41:08 CEST | PR-1200 glueing + 1kg pressure + LED + 16h |
Teststand results
Creation time | Detector | Notes |
---|---|---|
13. Sep 2018 17:51:22 CEST | VPTT | High Gain |
13. Sep 2018 17:51:22 CEST | VPTT | Low Gain |
Version history
Time | Author | Change comment |
---|---|---|
30. Mar 2022 18:54:58 CEST | seifen | Updated cosmis calibration results via API. |
20. Nov 2019 14:53:25 CET | cschnier | seems that crystal 785 and 784 swapped in their packagings -> check: 785 should be glued, but 785 is currently at Bochum -> 784 was therefore glued |
20. Nov 2019 10:01:41 CET | cschnier | seems that crystal 785 and 784 swapped in their packagings -> check: 785 should be glued, but 785 is currently at Bochum -> 784 was therefore glued |
23. Aug 2018 17:06:50 CEST | mario | Assigned to submodule by script |
23. Aug 2018 16:58:24 CEST | mario | Auto-created by unit assembly script |