RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA1180


This is all the information about the unit UA1180. If it is wrong, edit the data.

Unit specification:  
Database number: 158
Detector: Hamamatsu Vacuum Photo Tetrode UA1180
Submodule: 07052014-2 - 4-X1Y4-Eprevious (D) • in submodule • next (F)
Crystal: 4357
Barcode: 1309001446
   
Measured data:  
Yield (cosmics) for VPTT: 3.0326 ± 0.0318 at 888.3 V and -24 °C
Length: 75 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA1180
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 178
   
Measured data:  
DC gain: 51.44
Anode dark current: 0.02832 nA
Yield: 0
Notes:


Glueing photos

Creation time Notes
06. Jul 2017 14:35:22 CEST PR-1200 glueing + 1kg pressure + LED reglued


Upload new photo...

Teststand results

Creation time Detector Notes
04. Nov 2018 00:46:26 CET VPTT High Gain
04. Nov 2018 00:46:26 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:55:00 CEST seifen Updated cosmis calibration results via API.
01. Oct 2018 11:07:54 CEST fgrimm assigned to submodule
14. Sep 2018 14:55:42 CEST Tobias Unassigned from submodule because assignment was done according to old matching.
06. Jul 2017 14:34:32 CEST cschnier Assigned to alveole by script
06. Jul 2017 14:34:12 CEST cschnier Auto-created by unit assembly script