RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show unit UA1790


This is all the information about the unit UA1790. If it is wrong, edit the data.

Unit specification:  
Database number: 147
Detector: Hamamatsu Vacuum Photo Tetrode UA1790
Submodule: 20-11-2014-14:00 - 4-X0Y4-Eprevious (D) • in submodule • next (F)
Crystal: 4114
Barcode: 1309001651
   
Measured data:  
Yield (cosmics) for VPTT: 2.383 ± 0.0209 at 922.9 V and -24 °C
Length: 75 mm
   
Notes:


Detector

Detector specification:  
Serial number: UA1790
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 441
   
Measured data:  
DC gain: 47.14
Anode dark current: 0.061681 nA
Yield: -1
Notes:


Glueing photos

Creation time Notes
06. Jul 2017 14:12:44 CEST PR-1200 glueing + 1kg pressure + LED


Upload new photo...

Teststand results

Creation time Detector Notes
04. Nov 2018 00:44:00 CET VPTT High Gain
04. Nov 2018 00:44:00 CET VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:54:55 CEST seifen Updated cosmis calibration results via API.
21. Sep 2018 17:06:42 CEST fgrimm assigned to submodule
14. Sep 2018 14:54:34 CEST Tobias Unassigned from submodule because assignment was done according to old matching.
06. Jul 2017 14:11:49 CEST cschnier Assigned to alveole by script
06. Jul 2017 14:11:35 CEST cschnier Auto-created by unit assembly script