Unit specification:  
Database number: 140
Detector: Hamamatsu Vacuum Photo Tetrode UA1739
Submodule: 08072014-2 - 1-X2Y4-9previous (8) • in submodule • next (A)
Crystal: 3069
Barcode: 1309001583
   
Measured data:  
Yield (cosmics) for VPTT: 2.3292 ± 0.0159 at 961.4 V and -24 °C
Length: 75 mm
   
Notes: Formerly 16042014-2 1x1y5


Detector

Detector specification:  
Serial number: UA1739
Type: Hamamatsu Vacuum Photo Tetrode
Preamp: 78
   
Measured data:  
DC gain: 52.32
Anode dark current: 0.027937 nA
Yield: -1
Notes:


Glueing photos

Creation time Notes
06. Jul 2017 13:55:31 CEST PR-1200 glueing + 1kg pressure


Upload new photo...

Teststand results

Creation time Detector Notes
13. Sep 2018 17:50:45 CEST VPTT High Gain
13. Sep 2018 17:50:45 CEST VPTT Low Gain

 
 

Version history

Time Author Change comment
30. Mar 2022 18:54:14 CEST seifen Updated cosmis calibration results via API.
12. Jul 2018 15:50:12 CEST cschnier Formerly 16042014-2 1x1y5
06. Jul 2017 13:54:11 CEST cschnier Assigned to alveole by script
06. Jul 2017 11:46:28 CEST cschnier Auto-created by unit assembly script