Show unit UA0198
This is all the information about the unit UA0198. If it is wrong, edit the data.
Unit specification: | |
---|---|
Database number: | 13 |
Detector: | Hamamatsu Vacuum Photo Tetrode UA0198 |
Submodule: | unassigned |
Crystal: | 0 |
Barcode: | 1309000036 |
Measured data: | |
Yield (cosmics) for VPTT: | not yet measured/stored |
Length: | 77 mm |
Notes: | View through front face of crystal cover shows strange 'double refraction' - origin unknown (we checked that there is only one reflective crystal cover mounted) |
Detector
Detector specification: | |
---|---|
Serial number: | UA0198 |
Type: | Hamamatsu Vacuum Photo Tetrode |
Preamp: | 268 |
Measured data: | |
DC gain: | 48.61 |
Anode dark current: | 0.000948 nA |
Yield: | 0.8248 |
Notes: |
yield recorded w/o stable reference
relative value to all 16 units in the corresponding subunit only |
Glueing photos
Creation time | Notes |
---|---|
25. Jun 2014 00:37:16 CEST | |
21. Jan 2015 13:16:54 CET | Coupling between crystal and APDs after 7 months. Picture taken without alignment-tool. Some very small foreign objects visible. |
Teststand results
Creation time | Detector | Notes |
---|---|---|
No teststand results available! |
Version history
Time | Author | Change comment |
---|---|---|
07. Dec 2018 14:17:40 CET | cschnier | not attached to crystal anymore |
14. Sep 2018 14:44:44 CEST | Tobias | Unassigned from submodule because submodule was built for ELSA beamtime 2014 and has since been disassembled. |
21. Jan 2015 13:39:12 CET | cschnier | added picture |
23. Jul 2014 16:00:56 CEST | thomas | Added information to crystal cover foil |
23. Jul 2014 11:29:01 CEST | thomas | Assigned to alveole by script |
17. Jun 2014 13:33:18 CEST | cschnier | Auto-created by unit assembly script |