RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 526


This is all the information about the temperature sensor 526. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 526
Submodule: 17102014-3
Position: slot 8, right (looking to IP), front (towards IP)
Calibration polynomial:
(old standard)
T ( R ) = ( -2.360e+2 ± 0.000e+0 )  °C + ( 1.954e+0 ± 0.000e+0 ) °C Ω R + ( 3.138e-3 ± 0.000e+0 ) °C Ω 2 R 2 + ( -6.263e-6 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Miriam
Production date: 13. August 2015
R at room temperature: 119.5 Ω
   
Notes:


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:32:59 CET fhoelzken Updated sensor calibration via API.
14. May 2021 08:57:22 CEST oafedulidis
25. Aug 2015 17:20:46 CEST miriamk