RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 212 - Archived data from Tue, 25. August 2015 17:43:07 CEST


This is all the information about the temperature sensor 212. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 212
Submodule: O-Serie #4
Position: slot 0, top, back (towards backplate)
Calibration polynomial:
(old standard)
T ( R ) = ( -2.402e+2 ± 1.620e-2 )  °C + ( 1.847e+0 ± 2.135e-4 ) °C Ω R + ( 5.766e-3 ± 2.002e-6 ) °C Ω 2 R 2 + ( -1.829e-5 ± 1.366e-8 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Fanny
Production date: 19. November 2013
R at room temperature: 117 Ω
   
Notes:


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
09. Apr 2019 15:13:20 CEST miriamk formerly assigned submodule has been disassembled some time ago
25. Aug 2015 17:43:07 CEST miriamk Produced by, Production date, R at room temperature deduced from Proto192
25. Jul 2014 15:02:35 CEST thomas added sensor position
24. Jul 2014 18:51:52 CEST tobias Created based upon Miriam's calibration results.