RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 1928 - Archived data from Tue, 08. December 2020 17:21:48 CET


This is all the information about the temperature sensor 1928. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1928
Submodule: 26062014-03
Position: slot 4, right (looking to IP), front (towards IP)
Broken?: No
   
Production details:  
Produced by: Vincent
Production date: 16. September 2019
R at room temperature: 108.8 Ω
   
Notes: 2019-09-11 11:07 c printed, 2019-09-16 10:27 glued, 15:42-15:57 baked,repaired


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:35:06 CET fhoelzken Updated sensor calibration via API.
08. Dec 2020 17:21:48 CET jreher
27. Sep 2019 10:01:38 CEST petra