RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 1623


This is all the information about the temperature sensor 1623. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1623
Submodule: none
Position: none
Calibration polynomial:
(old standard)
T ( R ) = ( -1.872e+2 ± 0.000e+0 )  °C + ( 6.325e-1 ± 0.000e+0 ) °C Ω R + ( 1.393e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -3.899e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: Yes
   
Production details:  
Produced by: Vincent
Production date: 14. August 2019
R at room temperature: 121.8 Ω
   
Notes: 2019-08-14 08:47 b printed, 2019-08-16 11:18 glued, 15:22-15:37 baked, 9. wire was laid manually


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
06. Feb 2025 17:01:08 CET neichhorn Removed due to damage. New Sensor for 1-X7Y1 pos. 2 is Temp.-Sensor #306
06. Feb 2025 17:00:15 CET neichhorn Removed due to damage. New Sensor for 1-X7Y1 pos. 8 is Temp.-Sensor #306
02. Mar 2023 13:34:16 CET fhoelzken Updated sensor calibration via API.
10. Jun 2022 12:57:38 CEST oafedulidis
03. Sep 2019 14:03:30 CEST miriamk