Temperature sensor specification:  
Serial: 1616
Submodule: 21072015-1
Position: slot 4, right (looking to IP), front (towards IP)
Calibration polynomial:
(old standard)
T ( R ) = ( -1.962e+2 ± 0.000e+0 )  °C + ( 8.912e-1 ± 0.000e+0 ) °C Ω R + ( 1.238e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -3.504e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Vincent
Production date: 14. August 2019
R at room temperature: 119.2 Ω
   
Notes: 2019-08-14 07:58 a printed, 2019-08-16 11:12 glued, 15:22-15:37 baked


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:34:15 CET fhoelzken Updated sensor calibration via API.
19. May 2022 15:30:08 CEST oafedulidis
03. Sep 2019 13:57:06 CEST miriamk
03. Sep 2019 13:56:02 CEST miriamk