Temperature sensor specification:  
Serial: 1386
Submodule: 14102014-3
Position: slot E, bottom, back (towards backplate)
Calibration polynomial:
(old standard)
T ( R ) = ( -2.127e+2 ± 0.000e+0 )  °C + ( 1.396e+0 ± 0.000e+0 ) °C Ω R + ( 8.464e-3 ± 0.000e+0 ) °C Ω 2 R 2 + ( -2.352e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: No
   
Production details:  
Produced by: Vincent
Production date: 26. July 2019
R at room temperature: 115.9 Ω
   
Notes: 2019-07-24 09:12 b printed, 2019-07-26 11:43 glued, baking time 7min


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
02. Mar 2023 13:33:43 CET fhoelzken Updated sensor calibration via API.
14. May 2021 08:59:47 CEST oafedulidis
15. Aug 2019 13:46:03 CEST petra