RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show temperature sensor 1225


This is all the information about the temperature sensor 1225. If it is wrong, edit the data.


Attention: The calibration formula display below is written in MathML and optimized for Mozilla Firefox. If you cannot see it properly or your browser does not support MathML, use Firefox.

Temperature sensor specification:  
Serial: 1225
Submodule: none
Position: none
Calibration polynomial:
(old standard)
T ( R ) = ( -2.051e+2 ± 0.000e+0 )  °C + ( 1.179e+0 ± 0.000e+0 ) °C Ω R + ( 1.018e-2 ± 0.000e+0 ) °C Ω 2 R 2 + ( -2.834e-5 ± 0.000e+0 ) °C Ω 3 R 3
Calibration date: 01. January 1970
Broken?: Yes
   
Production details:  
Produced by: Vincent
Production date: 16. October 2018
R at room temperature: 118 Ω
   
Notes: printed sensor, glued with Polytec EC 242, acetone cleaned


Calibration Polynomials

Measurement Calibration Dataset Dataset Type
There are no calibration measurements linked to this sensor!


Version history

Time Author Change comment
27. Feb 2025 11:47:39 CET neichhorn Had to be exchanged due to damage. New Sensor for 2-X2Y5 is is #897
02. Mar 2023 13:33:28 CET fhoelzken Updated sensor calibration via API.
03. Sep 2020 12:42:43 CEST jreher
11. Jan 2019 14:58:40 CET vfreudenreich