RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0713006393 - Archived data from Tue, 21. July 2020 14:40:30 CEST


This is all the information about APD 0713006393. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0713006393
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 415 V
Voltage for Gain 100 (T=+25°C): 386.7 V
Dark current: 10.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 289
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 49
Position in grid: 17
Arrival for irradiation: 10. Jul 2016
Sent for analysis after irradiation: 22. Jul 2016
Return for assembly: 06. Oct 2016
   
Irradiation:  
Date: 12. Jul 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 1
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 12. Jul 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:34 CET jreher Updated box and position via API.
07. Oct 2020 15:44:48 CEST jreher Updated APD location via API.
11. Aug 2020 17:40:10 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:30 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:38 CET jreher Updated APD location via API.
25. Nov 2019 17:31:23 CET jreher Updated box and position via API.
22. Oct 2019 14:31:14 CEST spankonin Updated APD location via API.
14. Oct 2019 17:33:21 CEST jgrochowski Updated APD batch assignment via API.
06. Oct 2016 09:46:21 CEST markus.moritz Entered return for assembly date.
03. Aug 2016 16:01:35 CEST markus.moritz Entered shipped after irradiation date.
03. Aug 2016 16:01:10 CEST markus.moritz Entered arrival for irradiation date.
03. Aug 2016 15:59:10 CEST markus.moritz Entered shipped after irradiation date.
02. Aug 2016 14:57:08 CEST christopher.l.hahn Entered annealing information.
02. Aug 2016 13:57:35 CEST markus.moritz Entered irradiation information.
01. Aug 2016 17:52:04 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:13:10 CEST Tobias Imported from Hamamatsu datasheet.