RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1619018265 - Archived data from Wed, 16. June 2021 16:04:53 CEST


This is all the information about APD 1619018265. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1619018265
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E05
Break-through voltage: 414 V
Voltage for Gain 100 (T=+25°C): 385.4 V
Dark current: 5.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 301
Position in Box: 2
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 484
Position in grid: 17
Arrival for irradiation: 30. Oct 2017
Sent for analysis after irradiation: 17. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 16. Nov 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 4
Bias voltage: 385.4 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 385.608843 V     T = -25 °C: 349.7987042 V
Voltage for Gain 150: T = +20 °C: 393.5382376 V     T = -25 °C: 357.4314922 V
Voltage for Gain 200: T = +20 °C: 397.9253809 V     T = -25 °C: 361.9445713 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.366450707 V-1     T = -25 °C: 4.341393596 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.471009008 V-1     T = -25 °C: 8.654957679 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.61070467 V-1     T = -25 °C: 15.43662063 V-1
Break-through voltage: T = +20 °C: 410.7169876 V     T = -25 °C: 377.4737233 V
   
Notes:


Version history

Time Author Change comment
29. Mar 2022 12:38:40 CEST oafedulidis Assigned to capsule by script
16. Jun 2021 16:04:53 CEST oafedulidis Updated box and position via API.
16. Jun 2021 16:01:05 CEST oafedulidis Updated box and position via API.
16. Jun 2021 15:53:51 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:27:06 CET jreher Updated box and position via API.
11. Aug 2020 17:57:16 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:43:08 CEST jreher Updated APD location via API.
21. Jul 2020 14:42:58 CEST jreher Updated box and position via API.
19. Dec 2019 15:53:12 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:17:57 CET jreher Updated box and position via API.
17. Nov 2017 09:39:57 CET markus.moritz Entered shipped after irradiation date.
17. Nov 2017 09:38:49 CET markus.moritz Entered irradiation information.
09. Nov 2017 15:10:42 CET markus.moritz Entered arrival for irradiation date.
02. Nov 2017 15:16:52 CET Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 11:41:02 CEST Tobias Imported from Hamamatsu datasheet.