Subdetector specification: | |
---|---|
Serial: | 0712006358 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B06 |
Break-through voltage: | 409 V |
Voltage for Gain 100 (T=+25°C): | 380.7 V |
Dark current: | 12.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 297 |
Position in Box: | 5 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 51 |
Position in grid: | 8 |
Arrival for irradiation: | 03. Aug 2017 |
Sent for analysis after irradiation: | 23. Aug 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 11. Aug 2017 |
Dose used: | 46 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 380.7 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:26:34 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:56:37 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:46:10 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:42:10 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:42:01 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:48:06 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:27 CET | jreher | Updated box and position via API. |
23. Aug 2017 15:53:42 CEST | markus.moritz | Entered shipped after irradiation date. |
11. Aug 2017 14:10:48 CEST | hans-georg.zaunick | Entered irradiation information. |
07. Aug 2017 16:52:52 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
07. Aug 2017 16:43:41 CEST | hans-georg.zaunick | Entered arrival for irradiation date. |
04. Aug 2017 03:14:58 CEST | Tobias | Assigned to grid via information extracted from APD DB. |