Show Hamamatsu Avalanche Photo Diode 1612017706 - Archived data from Tue, 21. July 2020 14:43:09 CEST
This is all the information about APD 1612017706. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1612017706 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A06 |
Break-through voltage: | 419 V |
Voltage for Gain 100 (T=+25°C): | 391.4 V |
Dark current: | 4.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 301 |
Position in Box: | 14 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 465 |
Position in grid: | 11 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 17. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 391.4 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
26. Oct 2021 16:06:47 CEST | oafedulidis | Assigned to capsule by script |
17. May 2021 09:16:07 CEST | oafedulidis | Updated box and position via API. |
05. Feb 2021 11:27:07 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:57:18 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:09 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:42:59 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:54:10 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:58 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:39:50 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:38:37 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:12:20 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:56 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:45:35 CEST | Tobias | Imported from Hamamatsu datasheet. |