Show Hamamatsu Avalanche Photo Diode 1605017138 - Archived data from Fri, 16. April 2021 10:29:22 CEST
This is all the information about APD 1605017138. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1605017138 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C12 |
Break-through voltage: | 429 V |
Voltage for Gain 100 (T=+25°C): | 400 V |
Dark current: | 3.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 418 |
Position in Box: | 47 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Apr 2021 22:09:22 CEST | jreher | Updated APD characteristics via API. |
16. Apr 2021 10:29:22 CEST | jreher | Updated APD location via API. |
31. Mar 2021 14:15:10 CEST | jreher | Updated box and position via API. |
26. Feb 2021 15:46:56 CET | jreher | Updated APD batch assignment via API. |
03. Feb 2021 18:07:49 CET | jreher | Updated APD location via API. |
09. Nov 2017 16:49:02 CET | Tobias | Removed APD from grid as the grid arrived in Gießen without it. |
09. Nov 2017 15:11:55 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:56 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:43:26 CEST | Tobias | Imported from Hamamatsu datasheet. |