Show Hamamatsu Avalanche Photo Diode 1605017125 - Archived data from Tue, 11. August 2020 17:57:21 CEST
This is all the information about APD 1605017125. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1605017125 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C09 |
Break-through voltage: | 426 V |
Voltage for Gain 100 (T=+25°C): | 397.7 V |
Dark current: | 5.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 301 |
Position in Box: | 26 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 443 |
Position in grid: | 6 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 17. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 16. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 397.7 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 398.9427981 V T = -25 °C: 362.2992797 V |
Voltage for Gain 150: | T = +20 °C: 406.8086337 V T = -25 °C: 370.0151842 V |
Voltage for Gain 200: | T = +20 °C: 411.1645711 V T = -25 °C: 374.3180565 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.613686908 V-1 T = -25 °C: 4.581842542 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.174064581 V-1 T = -25 °C: 9.116882653 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.3493577 V-1 T = -25 °C: 14.25523689 V-1 |
Break-through voltage: | T = +20 °C: 425.6823921 V T = -25 °C: 389.0471027 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:09 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:57:21 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:10 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:00 CEST | jreher | Updated box and position via API. |
19. Dec 2019 15:54:11 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:17:59 CET | jreher | Updated box and position via API. |
17. Nov 2017 09:39:44 CET | markus.moritz | Entered shipped after irradiation date. |
17. Nov 2017 09:37:49 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:55 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:56 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:43:26 CEST | Tobias | Imported from Hamamatsu datasheet. |