Subdetector specification:  
Serial: 1605017110
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D15
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 394.3 V
Dark current: 3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 338
Position in Box: 47
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.2595231 V     T = -25 °C: 356.8083788 V
Voltage for Gain 150: T = +20 °C: 401.1762576 V     T = -25 °C: 364.4309852 V
Voltage for Gain 200: T = +20 °C: 405.5553978 V     T = -25 °C: 368.6922118 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.464087256 V-1     T = -25 °C: 4.840095596 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.781332377 V-1     T = -25 °C: 8.813488355 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.43288429 V-1     T = -25 °C: 15.49457842 V-1
Break-through voltage: T = +20 °C: 418.9497248 V     T = -25 °C: 382.7287391 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:45 CET jreher Updated APD characteristics via API.
15. Nov 2021 16:06:02 CET oafedulidis Updated APD location via API.
15. Nov 2021 16:05:44 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:59:08 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:39 CET jreher Updated box and position via API.
07. Oct 2020 15:45:44 CEST jreher Updated APD location via API.
17. Aug 2020 14:49:01 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:53:52 CEST jreher Updated APD location via API.
23. Jun 2016 10:43:25 CEST Tobias Imported from Hamamatsu datasheet.