RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1605017105 - Archived data from Mon, 15. November 2021 16:05:44 CET


This is all the information about APD 1605017105. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1605017105
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E15
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 394.1 V
Dark current: 3.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 338
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.2045357 V     T = -25 °C: 356.6923993 V
Voltage for Gain 150: T = +20 °C: 401.1265809 V     T = -25 °C: 364.319593 V
Voltage for Gain 200: T = +20 °C: 405.5047873 V     T = -25 °C: 368.5862309 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.462028287 V-1     T = -25 °C: 4.86842342 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.804519607 V-1     T = -25 °C: 8.855225195 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.4451481 V-1     T = -25 °C: 15.56793256 V-1
Break-through voltage: T = +20 °C: 418.6612744 V     T = -25 °C: 382.3329801 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:44 CET jreher Updated APD characteristics via API.
15. Nov 2021 16:06:02 CET oafedulidis Updated APD location via API.
15. Nov 2021 16:05:44 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:59:07 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:38 CET jreher Updated box and position via API.
07. Oct 2020 15:45:43 CEST jreher Updated APD location via API.
17. Aug 2020 14:49:01 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:53:51 CEST jreher Updated APD location via API.
23. Jun 2016 10:43:25 CEST Tobias Imported from Hamamatsu datasheet.