RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1605017101 - Archived data from Fri, 16. April 2021 21:59:06 CEST


This is all the information about APD 1605017101. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1605017101
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B03
Break-through voltage: 420 V
Voltage for Gain 100 (T=+25°C): 392.9 V
Dark current: 3.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 338
Position in Box: 38
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 392.5959337 V     T = -25 °C: 356.1377824 V
Voltage for Gain 150: T = +20 °C: 400.6264756 V     T = -25 °C: 363.8489488 V
Voltage for Gain 200: T = +20 °C: 405.0710722 V     T = -25 °C: 368.176182 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.337545944 V-1     T = -25 °C: 4.711238554 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.396243873 V-1     T = -25 °C: 9.348426084 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.46266088 V-1     T = -25 °C: 14.59080802 V-1
Break-through voltage: T = +20 °C: 418.776392 V     T = -25 °C: 383.2732013 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:43 CET jreher Updated APD characteristics via API.
15. Nov 2021 16:06:01 CET oafedulidis Updated APD location via API.
15. Nov 2021 16:05:43 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:59:06 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:38 CET jreher Updated box and position via API.
07. Oct 2020 15:45:43 CEST jreher Updated APD location via API.
17. Aug 2020 14:49:00 CEST vwerner Updated APD batch assignment via API.
11. Aug 2020 17:53:51 CEST jreher Updated APD location via API.
23. Jun 2016 10:43:25 CEST Tobias Imported from Hamamatsu datasheet.