Show Hamamatsu Avalanche Photo Diode 1604017029 - Archived data from Tue, 11. August 2020 17:57:24 CEST
This is all the information about APD 1604017029. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1604017029 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A06 |
Break-through voltage: | 413 V |
Voltage for Gain 100 (T=+25°C): | 386.7 V |
Dark current: | 6.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 301 |
Position in Box: | 41 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 439 |
Position in grid: | 2 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 10. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 10. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 386.7 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 386.1404846 V T = -25 °C: 350.1669208 V |
Voltage for Gain 150: | T = +20 °C: 394.1358838 V T = -25 °C: 357.769515 V |
Voltage for Gain 200: | T = +20 °C: 398.5793798 V T = -25 °C: 361.9702342 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.483335733 V-1 T = -25 °C: 4.785443725 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.727234912 V-1 T = -25 °C: 10.24361866 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.16574293 V-1 T = -25 °C: 15.45802512 V-1 |
Break-through voltage: | T = +20 °C: 410.4529471 V T = -25 °C: 376.0537086 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:10 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:57:24 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:11 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:01 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:18:42 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:00 CET | jreher | Updated box and position via API. |
10. Nov 2017 09:39:43 CET | markus.moritz | Entered shipped after irradiation date. |
10. Nov 2017 09:38:15 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:44 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:55 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:23 CEST | Tobias | Imported from Hamamatsu datasheet. |