Show Hamamatsu Avalanche Photo Diode 1603016942 - Archived data from Fri, 05. February 2021 11:29:56 CET
This is all the information about APD 1603016942. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1603016942 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B10 |
Break-through voltage: | 420 V |
Voltage for Gain 100 (T=+25°C): | 393 V |
Dark current: | 4.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 361 |
Position in Box: | 49 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.9805206 V T = -25 °C: 354.9724224 V |
Voltage for Gain 150: | T = +20 °C: 397.8830722 V T = -25 °C: 365.3439558 V |
Voltage for Gain 200: | T = +20 °C: 402.2705577 V T = -25 °C: 368.0393727 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.567609991 V-1 T = -25 °C: 35.36055924 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.056041314 V-1 T = -25 °C: 40.88088878 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.041405 V-1 T = -25 °C: 27.98364494 V-1 |
Break-through voltage: | T = +20 °C: 418.0403351 V T = -25 °C: 381.1294741 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Apr 2021 21:29:42 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:34:39 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:29:56 CET | jreher | Updated box and position via API. |
08. Sep 2020 17:13:48 CEST | vwerner | Updated APD batch assignment via API. |
11. Aug 2020 18:10:32 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:53:19 CEST | jreher | Updated APD location via API. |
21. Jul 2020 16:16:00 CEST | jreher | Updated APD batch assignment via API. |
09. Nov 2017 16:48:32 CET | Tobias | Removed APD from grid as the grid arrived in Gießen without it. |
09. Nov 2017 15:11:38 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:55 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:22 CEST | Tobias | Imported from Hamamatsu datasheet. |