Show Hamamatsu Avalanche Photo Diode 1603016927 - Archived data from Tue, 08. September 2020 17:13:47 CEST
This is all the information about APD 1603016927. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1603016927 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D07 |
Break-through voltage: | 416 V |
Voltage for Gain 100 (T=+25°C): | 387.3 V |
Dark current: | 5.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 361 |
Position in Box: | 47 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | none |
Position in grid: | none |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 393.5140447 V T = -25 °C: 355.6114858 V |
Voltage for Gain 150: | T = +20 °C: 401.4282924 V T = -25 °C: 362.7878094 V |
Voltage for Gain 200: | T = +20 °C: 405.8103798 V T = -25 °C: 367.9248934 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.416076142 V-1 T = -25 °C: 1.696470686 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.633995361 V-1 T = -25 °C: 45.65987773 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.11285549 V-1 T = -25 °C: 21.01345071 V-1 |
Break-through voltage: | T = +20 °C: 420.9673252 V T = -25 °C: 384.4463371 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Apr 2021 21:29:42 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:34:39 CET | jreher | Updated box and position via API. |
05. Feb 2021 11:29:55 CET | jreher | Updated box and position via API. |
08. Sep 2020 17:13:47 CEST | vwerner | Updated APD batch assignment via API. |
11. Aug 2020 18:10:29 CEST | jreher | Updated APD characteristics via API. |
11. Aug 2020 17:53:19 CEST | jreher | Updated APD location via API. |
21. Jul 2020 16:15:59 CEST | jreher | Updated APD batch assignment via API. |
09. Nov 2017 16:48:28 CET | Tobias | Removed APD from grid as the grid arrived in Gießen without it. |
09. Nov 2017 15:11:38 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:55 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:21 CEST | Tobias | Imported from Hamamatsu datasheet. |