RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1603016921 - Archived data from Fri, 05. February 2021 11:29:54 CET


This is all the information about APD 1603016921. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1603016921
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E08
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388 V
Dark current: 5.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 324
Position in Box: 20
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 1.027334046 V     T = -25 °C: 351.1155579 V
Voltage for Gain 150: T = +20 °C: 1.027334046 V     T = -25 °C: 358.9359583 V
Voltage for Gain 200: T = +20 °C: 1.027334046 V     T = -25 °C: 363.3614467 V
Gain/Voltage slope at M = 100: T = +20 °C: -620.2845253 V-1     T = -25 °C: 4.580258616 V-1
Gain/Voltage slope at M = 150: T = +20 °C: -620.2845253 V-1     T = -25 °C: 8.935834605 V-1
Gain/Voltage slope at M = 200: T = +20 °C: -620.2845253 V-1     T = -25 °C: 15.27352846 V-1
Break-through voltage: T = +20 °C: 416.6330746 V     T = -25 °C: 379.9285837 V
   
Notes:


Version history

Time Author Change comment
21. Apr 2021 12:56:58 CEST jreher Updated box and position via API.
05. Feb 2021 11:29:54 CET jreher Updated box and position via API.
11. Aug 2020 18:10:28 CEST jreher Updated APD characteristics via API.
11. Aug 2020 17:53:19 CEST jreher Updated APD location via API.
21. Jul 2020 16:15:44 CEST jreher Updated APD batch assignment via API.
23. Jun 2016 10:42:21 CEST Tobias Imported from Hamamatsu datasheet.