RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0711006268 - Archived data from Tue, 11. August 2020 17:40:25 CEST


This is all the information about APD 0711006268. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0711006268
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.4 V
Dark current: 18.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 290
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 44
Position in grid: 15
Arrival for irradiation: 20. Jun 2016
Sent for analysis after irradiation: 08. Jul 2016
Return for assembly: 04. Aug 2016
   
Irradiation:  
Date: 30. Jun 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 1
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 01. Jul 2016
Temperature: 80 °C
Duration: 8 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.8624777 V     T = -25 °C: 352.6307075 V
Voltage for Gain 150: T = +20 °C: 396.7620327 V     T = -25 °C: 360.1087929 V
Voltage for Gain 200: T = +20 °C: 401.134933 V     T = -25 °C: 364.3299392 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.621042579 V-1     T = -25 °C: 4.648621856 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.154063599 V-1     T = -25 °C: 9.267294383 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.25020951 V-1     T = -25 °C: 14.39744974 V-1
Break-through voltage: T = +20 °C: 416.024943 V     T = -25 °C: 379.1648958 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:45 CET jreher Updated box and position via API.
11. Aug 2020 17:40:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:42 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:51 CET jreher Updated APD location via API.
25. Nov 2019 17:31:29 CET jreher Updated box and position via API.
22. Oct 2019 14:32:01 CEST spankonin Updated APD location via API.
15. Oct 2019 11:02:53 CEST jgrochowski Updated APD batch assignment via API.
19. Jan 2017 11:10:45 CET tobias Added irradiation/annealing data after fixing PSL S/N issue.
18. Jan 2017 16:28:35 CET Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:13:07 CEST Tobias Imported from Hamamatsu datasheet.