RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 0711006268


This is all the information about APD 0711006268. If it is wrong, edit the data.

Subdetector specification:  
Serial: 0711006268
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B07
Break-through voltage: 417 V
Voltage for Gain 100 (T=+25°C): 388.4 V
Dark current: 18.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 290
Position in Box: 40
EP1 batch: none
EP1 batch after irradiation: 10203
   
Shipment:  
Grid number: 44
Position in grid: 15
Arrival for irradiation: 20. Jun 2016
Sent for analysis after irradiation: 08. Jul 2016
Return for assembly: 04. Aug 2016
   
Irradiation:  
Date: 30. Jun 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 1
Bias voltage: 320 V     (connection unknown)
   
Annealing:  
Date: 01. Jul 2016
Temperature: 80 °C
Duration: 8 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.8624777 V     T = -25 °C: 352.6307075 V
Voltage for Gain 150: T = +20 °C: 396.7620327 V     T = -25 °C: 360.1087929 V
Voltage for Gain 200: T = +20 °C: 401.134933 V     T = -25 °C: 364.3299392 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.621042579 V-1     T = -25 °C: 4.648621856 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.154063599 V-1     T = -25 °C: 9.267294383 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.25020951 V-1     T = -25 °C: 14.39744974 V-1
Break-through voltage: T = +20 °C: 416.024943 V     T = -25 °C: 379.1648958 V
   
Notes:


Characteristics

Temperature Measurement Notes
No characteristics available!


Upload new characteristic...

Progression of the current during irradiation

Upload time Notes
No data available!


Upload new progression data...

Version history

Time Author Change comment
05. Feb 2021 11:25:45 CET jreher Updated box and position via API.
11. Aug 2020 17:40:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:42 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:51 CET jreher Updated APD location via API.
25. Nov 2019 17:31:29 CET jreher Updated box and position via API.
22. Oct 2019 14:32:01 CEST spankonin Updated APD location via API.
15. Oct 2019 11:02:53 CEST jgrochowski Updated APD batch assignment via API.
19. Jan 2017 11:10:45 CET tobias Added irradiation/annealing data after fixing PSL S/N issue.
18. Jan 2017 16:28:35 CET Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:13:07 CEST Tobias Imported from Hamamatsu datasheet.