Show Hamamatsu Avalanche Photo Diode 1602016819 - Archived data from Tue, 11. August 2020 17:57:30 CEST
This is all the information about APD 1602016819. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1602016819 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E03 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 389.2 V |
Dark current: | 6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 302 |
Position in Box: | 23 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 431 |
Position in grid: | 0 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 20. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 20. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 389.2 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 389.7152371 V T = -25 °C: 353.4828445 V |
Voltage for Gain 150: | T = +20 °C: 397.6654089 V T = -25 °C: 361.0877884 V |
Voltage for Gain 200: | T = +20 °C: 402.0688521 V T = -25 °C: 365.3766394 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.326945703 V-1 T = -25 °C: 4.642036624 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.223120983 V-1 T = -25 °C: 9.175650694 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.38461081 V-1 T = -25 °C: 14.22801061 V-1 |
Break-through voltage: | T = +20 °C: 418.1850692 V T = -25 °C: 381.5227543 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Nov 2022 10:00:12 CET | oafedulidis | Assigned to capsule by script |
21. Apr 2021 12:51:25 CEST | jreher | Updated box and position via API. |
05. Feb 2021 11:27:16 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:57:30 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:25 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:15 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:19:02 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:07 CET | jreher | Updated box and position via API. |
20. Oct 2017 14:32:01 CEST | markus.moritz | Entered shipped after irradiation date. |
20. Oct 2017 09:52:13 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 11:31:42 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:54 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:19 CEST | Tobias | Imported from Hamamatsu datasheet. |