Show Hamamatsu Avalanche Photo Diode 1602016814 - Archived data from Wed, 07. October 2020 15:46:09 CEST
This is all the information about APD 1602016814. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1602016814 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B05 |
Break-through voltage: | 415 V |
Voltage for Gain 100 (T=+25°C): | 387.5 V |
Dark current: | 6.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 46 |
Position in Box: | 21 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 430 |
Position in grid: | 15 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 387.3174145 V T = -25 °C: 351.2811601 V |
Voltage for Gain 150: | T = +20 °C: 395.2481053 V T = -25 °C: 358.8947635 V |
Voltage for Gain 200: | T = +20 °C: 399.66797 V T = -25 °C: 363.1688515 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.547459431 V-1 T = -25 °C: 4.31833713 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.287497563 V-1 T = -25 °C: 8.799893588 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.83182142 V-1 T = -25 °C: 13.601572 V-1 |
Break-through voltage: | T = +20 °C: 414.0898155 V T = -25 °C: 377.8783313 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:54:08 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:52 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:46:09 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:27:13 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:37:09 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:33 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:53 CEST | jreher | Updated APD location via API. |
18. Jun 2019 13:30:07 CEST | jgrochowski | Updated APD batch assignment via API. |
18. Jan 2019 14:43:05 CET | markus.moritz | |
03. Dec 2018 14:05:21 CET | markus.moritz | |
29. Sep 2017 12:32:45 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:54 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:19 CEST | Tobias | Imported from Hamamatsu datasheet. |