Show Hamamatsu Avalanche Photo Diode 1601016796 - Archived data from Tue, 11. August 2020 17:26:14 CEST
This is all the information about APD 1601016796. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1601016796 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G08 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 390.1 V |
Dark current: | 6.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 40 |
Position in Box: | 29 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 428 |
Position in grid: | 17 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 390.6358488 V T = -25 °C: 354.6239776 V |
Voltage for Gain 150: | T = +20 °C: 398.5919531 V T = -25 °C: 362.2936396 V |
Voltage for Gain 200: | T = +20 °C: 402.9725652 V T = -25 °C: 366.5852552 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.334907771 V-1 T = -25 °C: 4.370299635 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.672826805 V-1 T = -25 °C: 8.373656953 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.09301118 V-1 T = -25 °C: 15.4941588 V-1 |
Break-through voltage: | T = +20 °C: 418.560682 V T = -25 °C: 382.4594762 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
15. Nov 2022 13:15:16 CET | oafedulidis | Assigned to capsule by script |
16. Dec 2021 13:42:18 CET | oafedulidis | Updated box and position via API. |
05. Feb 2021 10:53:23 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:09 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:26:14 CEST | jreher | Updated APD characteristics via API. |
27. Nov 2019 19:36:05 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:04 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:03 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:24 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:20 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 15:00:48 CET | markus.moritz | |
29. Sep 2017 13:46:17 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:52 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:19 CEST | Tobias | Imported from Hamamatsu datasheet. |