RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1601016789 - Archived data from Wed, 07. October 2020 14:22:38 CEST


This is all the information about APD 1601016789. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1601016789
Type: Hamamatsu Avalanche Photo Diode
Detector: assigned to 1601016789/2515028666
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: blue
   
Manufacturer information:  
Wafer position: E02
Break-through voltage: 409 V
Voltage for Gain 100 (T=+25°C): 380.9 V
Dark current: 6.1 nA
   
Screening Logistics:  
Available: No
Storage Box: 39
Position in Box: 48
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: none
Position in grid: none
Arrival for irradiation: none
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 381.7696312 V     T = -25 °C: 345.9736323 V
Voltage for Gain 150: T = +20 °C: 389.6710888 V     T = -25 °C: 353.4517137 V
Voltage for Gain 200: T = +20 °C: 394.0610187 V     T = -25 °C: 357.6737979 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.507605184 V-1     T = -25 °C: 4.727920469 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.695212762 V-1     T = -25 °C: 9.266599539 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.6779264 V-1     T = -25 °C: 15.97903944 V-1
Break-through voltage: T = +20 °C: 408.3793553 V     T = -25 °C: 372.2018218 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:17 CET jreher Updated box and position via API.
03. Feb 2021 18:19:04 CET jreher Updated box and position via API.
07. Oct 2020 14:22:38 CEST jreher Assigned to capsule by script
17. Aug 2020 15:53:53 CEST jreher Updated box and position via API.
11. Aug 2020 17:26:08 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:55 CET jreher Updated APD location via API.
25. Nov 2019 17:14:01 CET jreher Updated box and position via API.
04. Jul 2019 11:10:56 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:21 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:17 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 15:06:11 CET markus.moritz
23. Jun 2016 10:42:18 CEST Tobias Imported from Hamamatsu datasheet.