Show Hamamatsu Avalanche Photo Diode 1601016764 - Archived data from Tue, 11. August 2020 18:09:46 CEST
This is all the information about APD 1601016764. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1601016764 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A06 |
Break-through voltage: | 412 V |
Voltage for Gain 100 (T=+25°C): | 385.4 V |
Dark current: | 5.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 261 |
Position in Box: | 16 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 427 |
Position in grid: | 7 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 385.6429068 V T = -25 °C: 0 V |
Voltage for Gain 150: | T = +20 °C: 393.6184826 V T = -25 °C: 0 V |
Voltage for Gain 200: | T = +20 °C: 398.0521208 V T = -25 °C: 0 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.326583571 V-1 T = -25 °C: 0 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.222472332 V-1 T = -25 °C: 0 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.26770525 V-1 T = -25 °C: 0 V-1 |
Break-through voltage: | T = +20 °C: 411.8261317 V T = -25 °C: 376.5970384 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:21:55 CET | jreher | Updated box and position via API. |
11. Aug 2020 18:09:46 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:34:37 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:34:27 CEST | jreher | Updated box and position via API. |
29. Jun 2020 16:12:01 CEST | jreher | Updated APD batch assignment via API. |
01. Aug 2016 17:29:51 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:18 CEST | Tobias | Imported from Hamamatsu datasheet. |