Show Hamamatsu Avalanche Photo Diode 1601016748 - Archived data from Tue, 11. August 2020 17:25:18 CEST
This is all the information about APD 1601016748. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1601016748 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C04 |
Break-through voltage: | 417 V |
Voltage for Gain 100 (T=+25°C): | 388.2 V |
Dark current: | 5.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 34 |
Position in Box: | 48 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 426 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 388.7204832 V T = -25 °C: 352.3213733 V |
Voltage for Gain 150: | T = +20 °C: 396.647471 V T = -25 °C: 359.9529498 V |
Voltage for Gain 200: | T = +20 °C: 401.0717642 V T = -25 °C: 364.253236 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.614668215 V-1 T = -25 °C: 4.876838586 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.693823727 V-1 T = -25 °C: 9.29785789 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.49818148 V-1 T = -25 °C: 14.73326986 V-1 |
Break-through voltage: | T = +20 °C: 416.4063545 V T = -25 °C: 379.5241034 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:18 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:23 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:18 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:39 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:35 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:17 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:59 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:54 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:38:53 CET | markus.moritz | |
03. Dec 2018 13:58:17 CET | markus.moritz | |
29. Sep 2017 11:42:47 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:51 CEST | Tobias | Assigned to grid via information extracted from APD DB. |