Show Hamamatsu Avalanche Photo Diode 1601016747 - Archived data from Wed, 07. October 2020 12:18:41 CEST
This is all the information about APD 1601016747. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1601016747 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | assigned to 1601016747/2412026878 |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | blue |
Manufacturer information: | |
Wafer position: | G05 |
Break-through voltage: | 414 V |
Voltage for Gain 100 (T=+25°C): | 385.9 V |
Dark current: | 6.4 nA |
Screening Logistics: | |
Available: | No |
Storage Box: | 34 |
Position in Box: | 47 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 426 |
Position in grid: | 11 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 16. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 28. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 386.6119125 V T = -25 °C: 350.8489649 V |
Voltage for Gain 150: | T = +20 °C: 394.4162382 V T = -25 °C: 358.3714704 V |
Voltage for Gain 200: | T = +20 °C: 398.7559102 V T = -25 °C: 362.5984144 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.727036551 V-1 T = -25 °C: 4.764480261 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.132889767 V-1 T = -25 °C: 9.166570772 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.74245529 V-1 T = -25 °C: 14.7345155 V-1 |
Break-through voltage: | T = +20 °C: 409.2517448 V T = -25 °C: 377.8867234 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:17 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:23 CET | jreher | Updated box and position via API. |
07. Oct 2020 12:18:41 CEST | jreher | Assigned to capsule by script |
17. Aug 2020 15:53:59 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:25:18 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:39 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:35 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:17 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:59 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:54 CEST | jreher | Updated APD batch assignment via API. |
18. Jan 2019 14:38:48 CET | markus.moritz | |
03. Dec 2018 13:54:26 CET | markus.moritz | |
29. Sep 2017 11:42:47 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:51 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:17 CEST | Tobias | Imported from Hamamatsu datasheet. |