RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1601016740 - Archived data from Wed, 03. February 2021 18:18:23 CET


This is all the information about APD 1601016740. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1601016740
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E07
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 387.8 V
Dark current: 7.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 34
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 426
Position in grid: 4
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 388.2427593 V     T = -25 °C: 351.7952845 V
Voltage for Gain 150: T = +20 °C: 396.1360194 V     T = -25 °C: 359.3595642 V
Voltage for Gain 200: T = +20 °C: 400.5151061 V     T = -25 °C: 363.6181129 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.440177469 V-1     T = -25 °C: 4.739681898 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.194488323 V-1     T = -25 °C: 9.006466279 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.70307088 V-1     T = -25 °C: 14.26349508 V-1
Break-through voltage: T = +20 °C: 414.2529247 V     T = -25 °C: 377.234052 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:17 CET jreher Updated box and position via API.
03. Feb 2021 18:18:23 CET jreher Updated box and position via API.
11. Aug 2020 17:25:17 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:39 CET jreher Updated APD location via API.
25. Nov 2019 17:13:35 CET jreher Updated box and position via API.
13. Jun 2019 11:29:17 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:58 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:54 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:38:03 CET markus.moritz
03. Dec 2018 14:00:49 CET markus.moritz
29. Sep 2017 11:42:47 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:51 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:42:17 CEST Tobias Imported from Hamamatsu datasheet.