Show Hamamatsu Avalanche Photo Diode 1503016661 - Archived data from Tue, 11. August 2020 17:57:35 CEST
This is all the information about APD 1503016661. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1503016661 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | H08 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 390.6 V |
Dark current: | 4.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 302 |
Position in Box: | 44 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 429 |
Position in grid: | 11 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 10. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 08. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 390.6 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.4971706 V T = -25 °C: 355.2331076 V |
Voltage for Gain 150: | T = +20 °C: 399.4943551 V T = -25 °C: 362.9109636 V |
Voltage for Gain 200: | T = +20 °C: 403.923034 V T = -25 °C: 367.2264535 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.355724275 V-1 T = -25 °C: 4.657571879 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.387791706 V-1 T = -25 °C: 9.162337792 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.41316508 V-1 T = -25 °C: 14.3541068 V-1 |
Break-through voltage: | T = +20 °C: 414.065068 V T = -25 °C: 381.9808056 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
19. May 2022 15:29:29 CEST | oafedulidis | Assigned to capsule by script |
27. Aug 2021 11:10:48 CEST | oafedulidis | Updated box and position via API. |
21. Apr 2021 12:51:27 CEST | jreher | Updated box and position via API. |
05. Feb 2021 11:27:19 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:57:35 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:27 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:17 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:19:18 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:08 CET | jreher | Updated box and position via API. |
10. Nov 2017 09:39:27 CET | markus.moritz | Entered shipped after irradiation date. |
09. Nov 2017 15:01:38 CET | markus.moritz | Entered irradiation information. |
29. Sep 2017 11:39:18 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:53 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:15 CEST | Tobias | Imported from Hamamatsu datasheet. |