RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1503016644 - Archived data from Wed, 03. February 2021 18:18:20 CET


This is all the information about APD 1503016644. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1503016644
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E15
Break-through voltage: 416 V
Voltage for Gain 100 (T=+25°C): 390.9 V
Dark current: 4.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 34
Position in Box: 16
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 423
Position in grid: 15
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.3224229 V     T = -25 °C: 353.6891251 V
Voltage for Gain 150: T = +20 °C: 398.139885 V     T = -25 °C: 361.3827277 V
Voltage for Gain 200: T = +20 °C: 402.4938184 V     T = -25 °C: 365.6109601 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.466061974 V-1     T = -25 °C: 4.746453396 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.142375103 V-1     T = -25 °C: 8.744176235 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.08071647 V-1     T = -25 °C: 15.40382986 V-1
Break-through voltage: T = +20 °C: 415.4142551 V     T = -25 °C: 378.6339135 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:14 CET jreher Updated box and position via API.
03. Feb 2021 18:18:20 CET jreher Updated box and position via API.
11. Aug 2020 17:25:11 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:37 CET jreher Updated APD location via API.
25. Nov 2019 17:13:33 CET jreher Updated box and position via API.
13. Jun 2019 11:29:15 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:56 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:51 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 13:11:34 CET markus.moritz
29. Sep 2017 14:10:19 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:49 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:42:15 CEST Tobias Imported from Hamamatsu datasheet.