Show Hamamatsu Avalanche Photo Diode 1502016631 - Archived data from Tue, 11. August 2020 17:24:39 CEST
This is all the information about APD 1502016631. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1502016631 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G13 |
Break-through voltage: | 422 V |
Voltage for Gain 100 (T=+25°C): | 394.3 V |
Dark current: | 4.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 31 |
Position in Box: | 1 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 423 |
Position in grid: | 9 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 394.9288511 V T = -25 °C: 358.5066178 V |
Voltage for Gain 150: | T = +20 °C: 402.8893149 V T = -25 °C: 366.3027009 V |
Voltage for Gain 200: | T = +20 °C: 407.3275051 V T = -25 °C: 370.6855881 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.375883257 V-1 T = -25 °C: 4.640258987 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.075001731 V-1 T = -25 °C: 8.821273173 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.24188203 V-1 T = -25 °C: 14.73654438 V-1 |
Break-through voltage: | T = +20 °C: 420.0726179 V T = -25 °C: 385.9737697 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:51:49 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:17:54 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:39 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:01 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:17 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:31 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:40 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:35 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 13:09:59 CET | markus.moritz | |
29. Sep 2017 14:10:19 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:42:15 CEST | Tobias | Imported from Hamamatsu datasheet. |