Show Hamamatsu Avalanche Photo Diode 1502016611 - Archived data from Wed, 07. October 2020 15:45:01 CEST
This is all the information about APD 1502016611. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1502016611 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D13 |
Break-through voltage: | 426 V |
Voltage for Gain 100 (T=+25°C): | 397.1 V |
Dark current: | 4.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 303 |
Position in Box: | 12 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 422 |
Position in grid: | 12 |
Arrival for irradiation: | 30. Oct 2017 |
Sent for analysis after irradiation: | 10. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 10. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 1 |
Bias voltage: | 397.1 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 397.4532298 V T = -25 °C: 360.8281327 V |
Voltage for Gain 150: | T = +20 °C: 405.4418115 V T = -25 °C: 368.6041518 V |
Voltage for Gain 200: | T = +20 °C: 409.8553004 V T = -25 °C: 372.9381102 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.357028801 V-1 T = -25 °C: 4.693751244 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.395942774 V-1 T = -25 °C: 9.340360336 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.3253997 V-1 T = -25 °C: 14.52984624 V-1 |
Break-through voltage: | T = +20 °C: 425.5828198 V T = -25 °C: 388.9539321 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:27:23 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:01 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:57:38 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:43:40 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:43:30 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:19:19 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:13 CET | jreher | Updated box and position via API. |
10. Nov 2017 09:39:20 CET | markus.moritz | Entered shipped after irradiation date. |
10. Nov 2017 09:37:32 CET | markus.moritz | Entered irradiation information. |
09. Nov 2017 15:11:33 CET | markus.moritz | Entered arrival for irradiation date. |
02. Nov 2017 15:16:55 CET | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:41:04 CEST | Tobias | Imported from Hamamatsu datasheet. |