Show Hamamatsu Avalanche Photo Diode 1502016574 - Archived data from Tue, 11. August 2020 17:24:40 CEST
This is all the information about APD 1502016574. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1502016574 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B09 |
Break-through voltage: | 419 V |
Voltage for Gain 100 (T=+25°C): | 390.5 V |
Dark current: | 4.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 31 |
Position in Box: | 5 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 420 |
Position in grid: | 17 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 390.7848782 V T = -25 °C: 354.4126493 V |
Voltage for Gain 150: | T = +20 °C: 398.7192074 V T = -25 °C: 362.1002596 V |
Voltage for Gain 200: | T = +20 °C: 403.1281797 V T = -25 °C: 366.4110474 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.507267669 V-1 T = -25 °C: 4.84228722 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.732989045 V-1 T = -25 °C: 9.511996256 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.81624703 V-1 T = -25 °C: 14.58937893 V-1 |
Break-through voltage: | T = +20 °C: 418.7208559 V T = -25 °C: 382.3550832 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:51:49 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:17:54 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:40 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:02 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:17 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:32 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:41 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:36 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 14:18:51 CET | markus.moritz | |
29. Sep 2017 14:10:02 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:44 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:41:03 CEST | Tobias | Imported from Hamamatsu datasheet. |