Subdetector specification:  
Serial: 1502016574
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B09
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 390.5 V
Dark current: 4.8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 31
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 420
Position in grid: 17
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 390.7848782 V     T = -25 °C: 354.4126493 V
Voltage for Gain 150: T = +20 °C: 398.7192074 V     T = -25 °C: 362.1002596 V
Voltage for Gain 200: T = +20 °C: 403.1281797 V     T = -25 °C: 366.4110474 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.507267669 V-1     T = -25 °C: 4.84228722 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.732989045 V-1     T = -25 °C: 9.511996256 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.81624703 V-1     T = -25 °C: 14.58937893 V-1
Break-through voltage: T = +20 °C: 418.7208559 V     T = -25 °C: 382.3550832 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:49 CET jreher Updated box and position via API.
03. Feb 2021 18:17:54 CET jreher Updated box and position via API.
11. Aug 2020 17:24:40 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:02 CET jreher Updated APD location via API.
25. Nov 2019 17:13:17 CET jreher Updated box and position via API.
13. Jun 2019 11:28:32 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:41 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:36 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 14:18:51 CET markus.moritz
29. Sep 2017 14:10:02 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:44 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:41:03 CEST Tobias Imported from Hamamatsu datasheet.