Show Hamamatsu Avalanche Photo Diode 1502016563 - Archived data from Tue, 11. August 2020 17:24:37 CEST
This is all the information about APD 1502016563. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1502016563 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D14 |
Break-through voltage: | 425 V |
Voltage for Gain 100 (T=+25°C): | 396.6 V |
Dark current: | 3.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 30 |
Position in Box: | 42 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 420 |
Position in grid: | 8 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 397.2980763 V T = -25 °C: 360.4349731 V |
Voltage for Gain 150: | T = +20 °C: 405.2713653 V T = -25 °C: 368.2399646 V |
Voltage for Gain 200: | T = +20 °C: 409.7139563 V T = -25 °C: 372.6347258 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.609759476 V-1 T = -25 °C: 4.697954697 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.835511938 V-1 T = -25 °C: 9.012280469 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.89072376 V-1 T = -25 °C: 15.18255413 V-1 |
Break-through voltage: | T = +20 °C: 425.0017789 V T = -25 °C: 388.4130982 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:51:45 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:17:51 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:37 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:21:53 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:16 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:19:40 CEST | jreher | Updated APD location via API. |
13. Jun 2019 11:19:03 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:40 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:35 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 14:16:35 CET | markus.moritz | |
29. Sep 2017 14:10:01 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:44 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:41:03 CEST | Tobias | Imported from Hamamatsu datasheet. |