Subdetector specification:  
Serial: 1501016497
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C14
Break-through voltage: 427 V
Voltage for Gain 100 (T=+25°C): 398.8 V
Dark current: 3.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 34
Position in Box: 3
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 417
Position in grid: 11
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 398.6855553 V     T = -25 °C: 361.9105919 V
Voltage for Gain 150: T = +20 °C: 406.6601436 V     T = -25 °C: 369.683655 V
Voltage for Gain 200: T = +20 °C: 411.0582338 V     T = -25 °C: 374.0333941 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.428394328 V-1     T = -25 °C: 4.675775004 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.166471027 V-1     T = -25 °C: 9.292407216 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.02243753 V-1     T = -25 °C: 14.27928418 V-1
Break-through voltage: T = +20 °C: 426.4050055 V     T = -25 °C: 389.7836185 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:12 CET jreher Updated box and position via API.
03. Feb 2021 18:18:18 CET jreher Updated box and position via API.
11. Aug 2020 17:25:09 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:36 CET jreher Updated APD location via API.
25. Nov 2019 17:13:32 CET jreher Updated box and position via API.
13. Jun 2019 11:29:14 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:55 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:50 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 15:01:21 CET markus.moritz
29. Sep 2017 13:46:42 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:42 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:41:01 CEST Tobias Imported from Hamamatsu datasheet.