Show Hamamatsu Avalanche Photo Diode 1501016497 - Archived data from Tue, 11. August 2020 17:25:09 CEST
This is all the information about APD 1501016497. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1501016497 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | C14 |
Break-through voltage: | 427 V |
Voltage for Gain 100 (T=+25°C): | 398.8 V |
Dark current: | 3.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 34 |
Position in Box: | 3 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 417 |
Position in grid: | 11 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 26. Nov 2018 |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 23. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 398.6855553 V T = -25 °C: 361.9105919 V |
Voltage for Gain 150: | T = +20 °C: 406.6601436 V T = -25 °C: 369.683655 V |
Voltage for Gain 200: | T = +20 °C: 411.0582338 V T = -25 °C: 374.0333941 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.428394328 V-1 T = -25 °C: 4.675775004 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.166471027 V-1 T = -25 °C: 9.292407216 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.02243753 V-1 T = -25 °C: 14.27928418 V-1 |
Break-through voltage: | T = +20 °C: 426.4050055 V T = -25 °C: 389.7836185 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:12 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:18 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:09 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:36 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:32 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:14 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:55 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:50 CEST | jreher | Updated APD batch assignment via API. |
26. Nov 2018 15:01:21 CET | markus.moritz | |
29. Sep 2017 13:46:42 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:42 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:41:01 CEST | Tobias | Imported from Hamamatsu datasheet. |