Show Hamamatsu Avalanche Photo Diode 1417016463 - Archived data from Wed, 03. February 2021 18:18:04 CET
This is all the information about APD 1417016463. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1417016463 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E03 |
Break-through voltage: | 424 V |
Voltage for Gain 100 (T=+25°C): | 394.6 V |
Dark current: | 8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 32 |
Position in Box: | 11 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 416 |
Position in grid: | 7 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 29. Nov 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 30. Nov 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 395.1167523 V T = -25 °C: 358.6804086 V |
Voltage for Gain 150: | T = +20 °C: 403.0894784 V T = -25 °C: 366.3602117 V |
Voltage for Gain 200: | T = +20 °C: 407.5149758 V T = -25 °C: 370.6991389 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.618265538 V-1 T = -25 °C: 4.705874341 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.000151847 V-1 T = -25 °C: 7.884340921 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.81010193 V-1 T = -25 °C: 14.84923259 V-1 |
Break-through voltage: | T = +20 °C: 423.3196883 V T = -25 °C: 386.7419495 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:51:58 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:04 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:24:50 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:14 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:22 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:28:47 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:47:46 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:41 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 14:36:17 CET | markus.moritz | Entered shipped after irradiation date. |
03. Dec 2018 14:37:51 CET | markus.moritz | |
29. Sep 2017 12:30:55 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:41 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:41:00 CEST | Tobias | Imported from Hamamatsu datasheet. |