RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1417016424 - Archived data from Wed, 03. February 2021 18:18:59 CET


This is all the information about APD 1417016424. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1417016424
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: D10
Break-through voltage: 421 V
Voltage for Gain 100 (T=+25°C): 392.6 V
Dark current: 6.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 39
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 414
Position in grid: 14
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 16. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 28. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 30. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 393.3157715 V     T = -25 °C: 356.6083324 V
Voltage for Gain 150: T = +20 °C: 401.3182082 V     T = -25 °C: 364.371508 V
Voltage for Gain 200: T = +20 °C: 405.7847317 V     T = -25 °C: 368.6822478 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.433282337 V-1     T = -25 °C: 4.678642454 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.328922071 V-1     T = -25 °C: 8.597671157 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.1960117 V-1     T = -25 °C: 13.96230485 V-1
Break-through voltage: T = +20 °C: 420.6922987 V     T = -25 °C: 383.9601501 V
   
Notes:


Version history

Time Author Change comment
10. Jun 2022 12:28:47 CEST oafedulidis Assigned to capsule by script
30. Aug 2021 14:08:16 CEST oafedulidis Updated box and position via API.
05. Feb 2021 10:53:13 CET jreher Updated box and position via API.
03. Feb 2021 18:18:59 CET jreher Updated box and position via API.
11. Aug 2020 17:26:00 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:35:52 CET jreher Updated APD location via API.
25. Nov 2019 17:13:58 CET jreher Updated box and position via API.
04. Jul 2019 11:10:53 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:18 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:14 CEST jreher Updated APD batch assignment via API.
18. Jan 2019 14:33:23 CET markus.moritz Entered shipped after irradiation date.
03. Dec 2018 10:29:27 CET markus.moritz
29. Sep 2017 09:49:04 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:40 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:40:59 CEST Tobias Imported from Hamamatsu datasheet.